Field of Applications
Explosives Narcotics
Chemical Warfare Agents (CWA) Toxic gases
VOC MVOC
TIC
Biological agents
IUT Institut für Umwelttechnologien GmbH Volmerstraße 7b D-12489 Berlin
D
etek
tion
Confidential
Application fieldsSemiconductordoping gases
• HF• Cl2• HCl• NH3
• HBr• Diboran• BCl3• Silane
1. Process controlling and monitoring
2. Safety at work
3. Process optimalisation
Safety at work and process monitoring
Building Protection
IMS systems for air condition control( IMS + GC-IMS)
Disposal of shells and bombs
against chemical warfare agents (CWA)
Container fumigation
People screening
portal
wipe Test unit
Explosives and narcotics detection
BIO-IMS
IUT Institut für Umwelttechnologien GmbH Volmerstraße 7b D-12489 Berlin
D
etek
tion
Confidential
IUT device family (- 200)
GC IMS – 200i
VOCAnalyzer – 200
TotalVOC – 200i
PID based
IMS – 200i
GC IMS - 200
mobilestationary
IMS based
Multi gas / multi sensorVOCAnalyzer – 200i
IMS MINI – 200
TotalVOC – 200
FumiDetec –200
IUT Institut für Umwelttechnologien GmbH Volmerstraße 7b D-12489 Berlin
D
etek
tion
Confidential
FumiDetec - 2001. Detection principle Multi-gas / multi-sensor detector:
Ion Mobility Spectrometer (IMS)+ Photo-Ionozatiopn-Detector (PID) coupled to GC-PID+ Infrared (IR) sensor+ Electro-Chemical cell (EC)
2. Ionization IMS: Tritium (3H) (below the permitted limit)PID: Krypton UV-Lampe (10.6 eV)
• Sulfuryl difluoride • 1,2-Dibromoethane
• Methyl bromide • 1,2-Dichloroethane
• Phosphine • 1,3-Dichloropropene
• Hydrogen cyanide (HCN) • Benzene
3. Measurable compounds(Excerpet)
• Chloropicrin • Xylene
• Formaldehyde • Toluene
• Carbon dioxide (CO2) • Styrene
• Carbon monoxide (CO) • Ammonia
4. Sensitivity ppb range
5. Dimension 520 mm x 150 mm x 410 mm
6. Weight 12 kg incl. rechargeable battery
7. Housing Protection class IP55
8. Operation temperature -10 °C to +50 °C
9. Air moisture 0 % to 90 % RH
10. Data output • Integrated graphic display• Storage card• Serial interface: RS-232 connection to PC
11. Warming up time ~15 minutes
12. Measuring time 4 Minutes
13. Rechargeable battery Li-Ion battery; Operation time up to 8 hours
14. Power Power supply: 220 VACOptional: 110 VAC / 19 VDC
15. Carrier gas No carrier gas neededAmbient air is used
IUT Institut für Umwelttechnologien GmbH Volmerstraße 7b D-12489 Berlin
D
etek
tion
Confidential
Gas Measuring Station - Rotterdam
Since July 2010 two gas measuring stations equipped with FumiDetec devices are in permanent operation at the largest European container port in Rotterdam.
Several thousand containers were measured at these stations. A total average of about 1200 containers per month has been measured resulting into an inspection rate of about 60 containers per day.