1/19A30
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Series CA7Contactors
Rugged, space savingand modularSprecher + Schuhsnewest contactor forapplications up to75HP @ 460V
Over 100 years of design experiencehas produced Sprecher + Schuhsseventh generation contactor line.Te CA7 represents the most modernand flexible power contactor availabletoday, meeting the highest industrialapplication requirements.
Big performance in asmall packageA wide selection of eleven contactorsin four frame sizes covers the entireCA7 horsepower range (up to 75HP @460/575V). Six of the contactors areonly 45mm wide, an extremely smallfootprint for such rugged perfor-mance. A number of design featuresaccount for this efficiency, includinghigh contact pressure and bounce-free contacts, allowing the devices tohandle the high starting currents typi-cal of modern motors.
Type 1 and Type 2Coordination
Whether youre designing motor cir-cuits for use in North America, Europeor any other part of the world, all CA7contactors have been designed and
tested with respect to Type 1 and Type2 short circuit coordination. Find outmore in the CA7 Technical Informa-tion section in this chapter.
45mm(1 3/4)
9A12A16A23A
45mm(1 3/4)
30A37A
54mm(2 1/8)
43A
72mm(2 13/16)
60A72A85A97A
Advanced safety andreliability featuresTe entire CA7 line features me-chanically linked contacts, sometimesreferred to as positively guidedcontacts or force guided contacts.If a main power pole welds, adequate
clearances exist (0.3mm) to en-sure that the auxiliary contacts donot change state when coil power isremoved and the device tries to open.Tis is a requirement in safety circuitsper IEC 60947-5-1.
Reliability is further assured by cross-stamped auxiliary contacts, whichprovide multi-point reliability in lowcurrent, low voltage applications.
Advantages of ElectronicDC CoilCA7-9E through CA7-43E areprovided with DC coils that dramati-cally decrease wattage consumptionduring pull-in. Tis allows the use ofsmaller power supplies. Te electronicDC coil design brings the height ofthe contactor back down to the samesize as the AC version. Select CA7contactors are also available with atwo-winding DC coil that reducesthe size of the contactor as well as thehold-in values.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
2/19A31visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Special use contactors forspecialized applicationsTe CA7 line has been expanded to in-clude a number of contactors designedand labeled for specific industrialapplications. In all cases, these devicesare UL and CSA approved for thesespecialized uses.
Lighting contactors
Te CAL7 contactor can be usedto control a wide variety of lightingloads. Tese contactors are well suitedto handle the high inrush currentstypical of this application as well asother non-motor (resistive) loads. Bothmechanically held and electrically heldmodels are available for lighting loadapplications up to 20A, 30A and 60A.
Modular accessories arecommon to all devicesAll accessories are interchangeableamong all CA7 contactors and CS7control relays. Tis minimizes inven-tory requirements and maximizes flex-ibility. op and side mount auxiliarycontacts are available depending onyour application. A mechanical inter-lock with two built-in NC auxiliariesalso provides electrical interlocking ifdesired. Pneumatic and electronic tim-ers, surge suppressors and electronicinterface modules provide solutions foreven the most complex applications.
Reversible coil providestotal flexibilityWhen shipped, both coil connectionsare normally located at the top of thecontactor in preparation for mountingan overload relay at the bottom. Formulti-starter panels, however, the coilcan be reversed, which provides spaceto close-couple a K7 Motor CircuitController on the top of the contactor.CA7 contactors can either be orderedwith the coil reversed or may be easilyreversed in the field.
Dual power terminalsspeed wiringCA7-30 through 97 contactors aredesigned with two power terminals for
all three poles. Tis simplifies powerwiring of interconnected contactors inreversing, reduced voltage and two-speed applications. Preformed powerwiring connectors are also available forvirtually instantaneous wiring in theselabor intensive applications. Simplifiedwiring means less labor and less cost.
Top mounted
coil
Two power terminalson each pole
Dual power terminals assure hassle-free wirin
in complex control schemes
Reversible coils are standard on all
CA7 contactors
Bottom
mounted coil
Sprecher + Schuhs expanded CA7 line includes
contactors designed and labeled for specific
industrial applications
CAL7 Lighting
Contactor
CAN7 NEMA
labeled contactor
CNX Special Purpose
Contactor
NEMA Labeled ContactorsCAN7 contactors are UL Listed andrated in accordance with the require-ments of NEMA standards publicatioICS-2. Tese contactors are NEMAcompliant and are labeled accordingly
Special purpose contactorsCNX contactors are standard CA7contactors that have been tested, ap-
proved and labeled by UL for heat-ing ventilation and air conditioning(HVAC) applications.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
3/19A32
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Contactors - AC Coil
Three Pole - Series CA7
Non-Reversing, Three Pole Contactors With AC Coil, Series CA7(Open type only)
Coil Codes
AC1 Resistive Ratings and UL/CSA Continuous Current Ratings may be increasedby the use of Lug Kits or Paralleling Links. See CA7 Accessories section for ap-plicable information.
Other voltages available, see page A56. Non-standard coil voltages not listed heremust be ordered and installed separately as renewal parts.
Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil
terminals located on the line side (top) of the contactor. Thisis the typical configuration when using the contactor with anoverload relay. When the contactor is used with the KT7 Motor
Circuit Controller, the coil must be reversed, so that the coilterminals are located at the load side (bottom) of the contactor.
CA7 coils can easily be reversed in the field, however, they arealso available for order with the coils reversed from the factory.
Contact your Sprecher+Schuh representative for more infor-mation about ordering CA7 contactors with reversed coils.
All CA7 contactors come with
reversible coils.
CA7-9-10 contactor
CA7-43-00 contactor
CA7-60-00 contactor
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4)Auxiliary
Contacts per
Contactor
Open Type
CatalogNumber Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V400V /415V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/21 0 CA7-9-10-
1200 1 CA7-9-01-
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 101 0 CA7-12-10-
1550 1 CA7-12-01-
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 151 0 CA7-16-10-
1740 1 CA7-16-01-
23 32 7.5 11 13 10 2 3 5 7-1/2 15 151 0 CA7-23-10-
1930 1 CA7-23-01-
30 65 10 15 15 15 2 5 7-1/2 10 20 25
0 0 CA7-30-00- 222
1 0 CA7-30-10- 244
0 1 CA7-30-01- 244
37 65 11 18.5/20
20 18.5 3 5 10 10 25 30
0 0 CA7-37-00- 266
1 0 CA7-37-10- 288
0 1 CA7-37-01- 288
43 85 13 22 25 22 3 7-1/2 10 15 30 30
0 0 CA7-43-00- 286
1 0 CA7-43-10- 308
0 1 CA7-43-01- 308
60 100 18.5 32 37 32 5 10 15 20 40 50
0 0 CA7-60-00- 350
1 0 CA7-60-10- 372
0 1 CA7-60-01- 372
72 100 22 40 45 40 5 15 20 25 50 60
0 0 CA7-72-00- 403
1 0 CA7-72-10- 425
0 1 CA7-72-01- 425
85 100 25 45 55 45 7-1/2 15 25 30 60 60
0 0 CA7-85-00- 460
1 0 CA7-85-10- 482
0 1 CA7-85-01- 482
97 130 30 55 55 55 10 20 30 30 75 75 0 0CA7-97-00- 577
1 0 CA7-97-10- 599
0 1 CA7-97-01- 599
AC
Coil Code
Voltage Range
50 Hz 60 Hz
24Z 24V 24V
120 110V 120V
208 ~ 208V
220W 200V-220V 208V-240V
240 220V 240V
277 240V 277V
380 380V-400V 440V
480 440V 480V
600 550v 600V
Ordering InstructionsSpecify Catalog Number
Replace () with Coil CodeSee Coil Codeson this page.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
4/19A33visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Contactors - AC Co
Four Pole - Series CA
Non-Reversing, Four Pole Contactors With AC Coil, Series CA7(Open type only)
Other voltages available, see page A56. Non-standard coil voltages not listed hermust be ordered and installed separately as renewal parts.
Coil Codes
CA7-23-M22-120 contactor
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4)Contact
Configuration,Main Pole
Open Type
CatalogNumber Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V400V415V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2432
012
CA7-9-M40-
CA7-9-M31-
CA7-9-M22-
120
132
132
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10432
012
CA7-12-M40-
CA7-12-M31-
CA7-12-M22-
157
167
167
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15432
012
CA7-16-M40-
CA7-16-M31-
CA7-16-M22-
176
186
186
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15
4
32
0
12
CA7-23-M40-
CA7-23-M31-CA7-23-M22-
194
206206
37 75 11 18.5 20 18.5 3 5 10 10 25 30 4 0 CA7-40-M40- 385
37 75 11 18.5/20 18.5 7.5 3 5 10 10 25 15 2 2 CA7-40-M22- 385
85 130 25 45 55 45 7-1/2 15 25 30 60 50 4 0 CA7-90-M40- 657
85 130 25 45 55 18.5 7-1/2 15 25 30 50 20 2 2 CA7-90-M22- 657
AC
Coil Code
Voltage Range
50 Hz 60 Hz
24Z 24V 24V
120 110V 120V
208 ~ 208V
220W 200V-220V 208V-240V
240 220V 240V
277 240V 277V
380 380V-400V 440V
480 440V 480V600 550V 600V
Ordering InstructionsSpecify Catalog Number
Replace () with Coil CodeSee Coil Codeson this page.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
5/19
A34
Co
ntactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
CA7-37E-00-24E contactor
Contactors - Low Consumption Electronic DC Coil
Three Pole - Series CA7
Non-Reversing, Three Pole Contactors With Electronic DC Coil, Series CA7(Open type only)
AC1 Resistive Ratings and UL/CSA Continuous Current Ratings may be increased by the use of
Lug Kits or Paralleling Links. See CA7 Accessories section for applicable information.
CA7-9E43E with electronic coils are not interchangeable with non-electronic DC or AC coils.
See page A47 for limitations on adding auxiliaries to Electronic DC Coil contacts.
Voltages of 48V DC and greater are supplied with backpack module standard. See page A85.
Not applicable with Electronic Timer accessories (CRZ_7).
Description
Low Consumption Electronic DC coils have extremely low
inrush which allows the use of smaller power supplies.
CA7-9E43E has internal surge suppression. See page A68 for
more information.
This new design results in:
Lighter, lower depth
More energy efcient contactors
Easier wiring Uniform panel appearance.
Applications
Direct control from PLC:
The low power consumption contactor designed to control
motors and other loads is especially aligned to the specic
requirement of electronic control circuits. The low power
consumption of 1.7 allows direct control through PLCs
without the need for interposing relays. Power dissipation is
greatly reduced limiting the heat effect in control panels.
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4)Auxiliary
Contacts perContactor
Open Type
CatalogNumber Price
kW(50 Hz) UL/CSA HP (60 Hz)
230V
400V/
415V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/21
0
0
1
CA7-9E-10-
CA7-9E-01-197
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 101
0
0
1
CA7-12E-10-
CA7-12E-01-242
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 151
0
0
1
CA7-16E-10-
CA7-16E-01-267
23 32 7.5 11 13 10 2 3 5 7-1/2 15 151
0
0
1
CA7-23E-10-
CA7-23E-01-292
30 65 10 15 15 15 2 5 7-1/2 10 20 25
0
1
0
0
0
1
CA7-30E-00-
CA7-30E-10-
CA7-30E-01-
332
354
354
37 65 11 18.5/20
20 18.5 3 5 10 10 25 30
0
1
0
0
0
1
CA7-37E-00-
CA7-37E-10-
CA7-37E-01-
392
414414
43 85 13 22 25 22 3 7-1/2 10 15 30 30
0
1
0
0
0
1
CA7-43E-00-
CA7-43E-10-
CA7-43E-01-
455
475
475
Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil terminals
located on the line side (top) of the contactor. This is the typical
conguration when using the contactor with an overload relay. When
the contactor is used with the KT7 Motor Circuit Controller, the coil
must be reversed, so that the coil terminals are located at the load
side (bottom) of the contactor. CA7 coils can easily be reversed in the
eld, however, they are also available for order with the coils reversed
from the factory. Contact your Sprecher+Schuh representative for more
information about ordering CA7 contactors with reversed coils.
All CA7 contactors come withreversible coils.(48V DC shown)
Coil Codes
DC Coil Codes Voltage
12E 12V
24E 24V
48E 48-72V
110E 110-125V
220E 220-250V
CA7-23E-10-24E contactor
CA7-16E-10-110E contactor
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
6/19
A35visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Contactors - Low Consumption Electronic DC Co
Four Pole - Series CA
Non-Reversing, Four Pole Contactors With Electronic DC Coil, Series CA7(Open type only)
CA7-23E-M22-24E contactor
Ie
[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4)Contact
Configuration,
Main Pole
Open Type
Catalog Number Price
kW (50 Hz) UL/CSA HP(60 Hz)
230V
400V
415V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2
4
3
2
0
1
2
CA7-9E-M40-
CA7-9E-M31-
CA7-9E-M22-
198
210
210
12 32 1 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10
4
3
2
0
1
2
CA7-12E-M40-
CA7-12E-M31-
CA7-12E-M22-
240
252
252
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15
4
3
2
0
1
2
CA7-16E-M40-
CA7-16E-M31-
CA7-16E-M22-
264
277
277
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15
4
3
2
0
1
2
CA7-23E-M40-
CA7-23E-M31-
CA7-23E-M22-
290
302
302
37 75 11 18.5 20 18.5 3 5 10 10 25 30 4 0 CA7-40E-M40- 520
37 75 11 18.5/20 18.5 7.5 3 5 10 10 25 15 2 2 CA7-40E-M22- 535
CA7-9E43E with electronic coils are not interchangeable with non-electronic DC or AC coils
See pages A47 for limitations on adding auxiliaries to Electronic DC Coil contacts.
Voltages of 48V DC and greater are supplied with backpack module standard. See page A85.
Not applicable with Electronic Timer accessories (CRZ_7).
Coil Codes
DC Coil Codes Voltage
12E 12V
24E 24V
48E 48-72V
110E 110-125V
220E 220-250V
Description
Low Consumption Electronic DC coils have extremely low inrush
which allows the use of smaller power supplies. CA7-9E43E have
internal surge suppression. See page A68 for more information.
This design results in:
Lighter, lower depth
More energy efcient contactors
Easier wiring
Uniform panel appearance
Applications
Direct control from PLC:
The low power consumption contactor designed to control motors
and other loads is especially aligned to the specic requirement of
electronic control circuits. The low power consumption of 1.7 allows
direct control through PLCs without the need for interposing relays.
Power dissipation is greatly reduced limiting the heat effect in control
panels.
Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil terminals
located on the line side (top) of the contactor. This is the typical
conguration when using the contactor with an overload relay. When
the contactor is used with the KT7 Motor Circuit Controller, the coil
must be reversed, so that the coil terminals are located at the load
side (bottom) of the contactor. CA7 coils can easily be reversed in the
eld, however, they are also available for order with the coils reversed
from the factory. Contact your Sprecher+Schuh representative for more
information about ordering CA7 contactors with reversed coils.
All CA7 contactors come withreversible coils.(48V DC shown)
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
7/19A36
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Contactors - Two Winding DC Coil
Three & Four Pole - Series CA7
Non-Reversing, Three Pole Contactors With Two Winding DC Coil, Series CA7(Open type only)
CA7-60DCA7-97D have an internal auxiliary contact to transition from the start windingto the run winding.
Coils include an integrated diode surge suppressor.Other coil voltages are available, see page A57. Contact your Sprecher + Schuh Sales Rep-
resentative to determine which coil voltages may be stocked.Non-standard coil voltages(non-stock) must be ordered and installed separately as renewal parts.
The coil codes shown are the most commonly stocked items. Contact your Sprecher +Schuh representative to determine if other voltages, i.e.., 12DD, 48DD, 220DD are on-handor can be specially ordered in quantities.
CA7-60D Contactor
Description:
Contactors with two
winding DC coils have very
low hold-in values and
share the same dimensions
with AC contactors. Seepage A57 for more informa-
tion. See page A84 for
dimensional information.
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4) AuxiliaryContacts per
Contactor
Open Type
Catalog Number Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V400V/415V 500V 690V
1 3 AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
60 100 18.5 32 37 32 5 10 15 20 40 50
0 0 CA7-60D-00- 475
1 0 CA7-60D-10- 497
0 1 CA7-60D-01- 497
72 100 22 40 45 40 5 15 20 25 50 60
0 0 CA7-72D-00- 530
1 0 CA7-72D-10- 552
0 1 CA7-72D-01- 552
85 100 25 45 55 45 7-1/2 15 25 30 60 60
0 0 CA7-85D-00- 590
1 0 CA7-85D-10- 612
0 1 CA7-85D-01- 612
97 130 30 55 55 55 10 20 30 30 75 75
0 0 CA7-97D-00- 757
1 0 CA7-97D-10- 779
0 1 CA7-97D-01- 779
Coil Codes
DC Coil Code Voltage
24DD 24V
110DD 110V
Ordering Instruct ionsSpecify Catalog Number
Replace () with Coil CodeSee Coil Codeson this page.
Non-Reversing, Four Pole Contactors With Two Winding DC Coil, Series CA7(Open type only)
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4) Contact Con-
figuration
Main Pole
AuxiliaryContacts per
Contactor
Open Type
Catalog Number Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V
415V
400V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC NO NC
85 130 25 45 55 45 7-1/2 15 25 30 60 50 4 0 0 0 CA7-90D-M40- 781
85 130 25 45 55 18.5 7-1/2 15 25 30 50 20 2 2 0 0 CA7-90D-M22- 781
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
8/19A37visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
CAU7-9-22-120 reversing contacto
CAU7-43-22-120 reversing contact
Reversing, Three Pole Contactors With AC Coil, Series CAU7(Open type only)
For Reversing Contactors without power wiring add suffix -LW to catalog numband deduct the following amount:
CAU7-923 deduct $10CAU7-3037 deduct $12CAU7-43 deduct $22
CAU7-6097 without power wiring not availableEx: CAU7-9-22-becomes CAU7-9-22--LW.
For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-9-22-becomes CAU7-9-22--CW.
The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.
The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.
Other voltages available, see page A56.Nonstandard coil voltages not listed here mbe ordered and installed separately as renewal parts.
Contactors, AC Coil Reversin
Three Pole - Series CAU
Includes:
Line side coil terminations Mechanical and electrical
Interlock
Reversing power wiring(using Power Wiring KitCat.# CAUT7-PW)
Control wiring available; se
footnote
Coil Codes
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary
Contacts per
Contactor
Open Type
Catalog
Number Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V
400V
415V 500V 690V
1 3
AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 1 1 CAU7-9-22- 338
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 1 CAU7-12-22- 409
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 1 CAU7-16-22- 451
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 1 CAU7-23-22- 491
30 65 10 15 15 15 2 5 7-1/2 10 20 250 1 CAU7-30-02- 553
1 1 CAU7-30-22- 597
37 65 11 18.5/20 20 8.5 3 5 10 10 25 300 1 CAU7-37-02- 640
1 1 CAU7-37-22- 684
43 85 13 22 25 22 3 7-1/2 10 15 30 300 1 CAU7-43-02- 710
1 1 CAU7-43-22- 754
60 100 18.5 32 37 32 5 10 15 20 40 500 1 CAU7-60-02- 895
1 1 CAU7-60-22- 939
72 100 22 40 45 40 5 15 20 25 50 600 1 CAU7-72-02- 1010
1 1 CAU7-72-22- 1054
85 100 25 45 55 45 7-1/2 15 25 30 60 600 1 CAU7-85-02- 1125
1 1 CAU7-85-22- 1169
97 130 30 55 55 55 10 20 30 30 75 750 1 CAU7-97-02- 1410
1 1 CAU7-97-22- 1454
AC Coil
Code
Voltage Range
50 Hz 60 Hz
24Z 24V 24V
120 110V 120V
208 ~ 208V
220W 200V-220V 208V - 240V
240 220V 240V
277 240V 277V
380 380V-400V 440V
480 440V 480V
600 550V 600V
Ordering InstructionsSpecify Catalog Number
Replace () with Coil CodeSee Coil Codeson this page.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
9/19
A38
Co
ntactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Contactors, Low Consumption Electronic DC Coil Reversing
Three Pole - Series CAU7
Reversing, Three Pole Contactors With Electronic DC Coil, Series CAU7(Open type only)
For Reversing Contactors without power wiring add suffix -LW to catalog numberand deduct the following amount:
CAU7-9E23E deduct $10CAU7-30E37E deduct $12Ex: CAU7-9E-22-24Ebecomes CAU7-9E-22-24E-LW.
For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-9E-22-24Ebecomes CAU7-9E-22-24E-CW.
The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.
The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.
CA7-9E43E with electronic coils are not interchangeable with non-electronic DCor AC coils.
See pages A47 for limitations. on adding auxiliaries to Electronic DC Coil contacts.Voltages of 48V DC and greater are supplied with backpack module standard. See
page A85.Not applicable with Electronic Timer accessories (CRZ_7).
CAU7-9E-22-24E Reversing contactor
CAU7-37E-22-24E Reversing contactor
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary
Contacts per
Contactor
Open Type
Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V
400V
415V 500V 690V
1 3
Catalog NumberAC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 1 1 CAU7-9E-22- 484
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 1 CAU7-12E-22- 597
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 1 CAU7-16E-22- 629
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 1 CAU7-23E-22- 679
30 65 10 15 15 15 2 5 7-1/2 10 20 250 1 CAU7-30E-02- 780
1 1 CAU7-30E-22- 820
37 65 1118.5/
2020 8.5 3 5 10 10 25 30
0 1 CAU7-37E-02- 971
1 1 CAU7-37E-22- 1018
43 85 13 22 25 22 3 7-1/2 10 15 30 30
0 1 CAU7-43E-02- 1050
1 1 CAU7-43E-22- 1090
Description
Low Consumption Electronic DC coils have
extremely low inrush which allows the use of
smaller power supplies. CA7-9E43E have
internal surge suppression. See page A68 for more
information.
This new design results in:
Lighter, lower depth
More energy efcient contactors
Easier wiring
Uniform panel appearance
Applications
Direct control from PLC:
The low power consumption contactor designed
to control motors and other loads is especially
aligned to the specific requirement of electronic
control circuits. The low power consumption of
1.7 allows direct control through PLCs without
the need for interposing relays. Power dissipation
is greatly reduced limiting the heat effect in
control panels.
Includes:
Line side coil terminations
Mechanical and electrical Interlock
Reversing power wiring (using Power Wiring Kit
Cat.# CAUT7-PW) Control wiring available; see footnote
CAU7-9E43E has internal surge suppression.
Coil Codes
DC Coil Codes Voltage
12E 12V
24E 24V
48E 48-72V
110E 110-125V
220E 220-250V
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
10/19A39visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Contactors, DC Coil Reversin
Three Pole - Series CAU
Reversing, Three Pole Contactors With DC Coil, Series CAU7(Open type only)
For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-60D-22-becomes CAU7-60D-22--CW.
The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.
The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.
Other voltages available, see page A57. Non-standard coil voltages not listed hermust be ordered and installed separately as renewal parts.
Coils for CAU7-60D97D reversing contactors include an integrated diode surgesuppressor.
Coil Codes
CAU7-85D Reversing (Typical)
NOTE: DC and AC coils are not interchangeable. CA7-60D97D contactors have a two winding, 3-leadcoil with built-in late break auxiliary contact and coil suppression. Refer to dimensions starting onpage A86.
Includes:
DC operating mechanism Line side coil terminations
Mechanical and electricalInterlock
Reversing power wiring Control wiring available; se
footnote
Ie[A]
Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary
Contacts per
Contactor
Open Type
Price
kW(50 Hz) UL/CSA HP(60 Hz)
230V400V415V 500V 690V
1 3 Catalog
NumberAC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC
60 100 18.5 32 37 32 5 10 15 20 40 500 1 CAU7-60D-02- 1115
1 1 CAU7-60D-22- 1159
72 100 22 40 45 40 5 15 20 25 50 600 1 CAU7-72D-02- 1240
1 1 CAU7-72D-22- 1284
85 100 25 45 55 45 7-1/2 15 25 30 60 600 1 CAU7-85D-02- 1360
1 1 CAU7-85D-22- 1410
97 130 30 55 55 55 10 20 30 30 75 750 1 CAU7-97D-02- 1745
1 1 CAU7-97D-22- 1789
DC Coil Code Voltage
12DD 12V
24DD 24V
48DD 48V
110DD 110V
220DD 220V
Ordering Instructions
Specify Catalog Number
Replace () with Coil CodeSee Coil Codeson this page.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
11/19A47visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Accessories Field Installab
CA7 Contacto
Max. number of auxiliary contacts that may be mounted:
AC Coil and Electronic DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O. contacts on the side, 4-N.C. front or side: 6 total.
True DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max. 2-N.O. contacts on side, 4-N.C. front or side: 4 total.
Detailed ratings can be found on page A74.
Contact Block Description NO NC
Contact
Arrangement For use with...
StandardContactsCatalog
Number Price
BifurcatedContactsCatalog
Number Pric
Auxiliary Contact Blocks forTop Mounting -
2 and 4 pole
Snap on design - mountswithout tools
Electronic compatiblecontacts
Mutual positive guidance tothe main contactor poles(excluding L types)
Several terminal numberingchoices even for modelswit equal function
Late break /early make (L)available
Bifurcated Contacts
Bifurcated auxiliary contacts
provides a higher degree of
reliability than the standardcross-stamped auxiliary
contacts because it H-bridge
divides each movable contact
into two sections at the
tip of the spanner. Typical
application is low-voltage
low-current applications
(i.e.: PLC). Cross-stamped
contacts are good for a mini-
mum of 5mA at 17v while
bifurcated contacts are good
for a minimum of 3mA at 5v.
0 252
51
62
61
CA7 all CS7-PV-02 27 CS7-PVB-02 42
CA7-30...97--00 CA7-PV-02 27 CA7-PVB-02 42
1 1
54
53
62
61
CA7 all CS7-PV-11 27 CS7-PVB-11 42
CA7-30...97--00 CA7-PV-11 27 CA7-PVB-11 42
CA7-9...23--10CA7-PV-S11 27 CA7-PVB-S11 42
CA7-9...23--01
2 054
53
64
63
CA7 all CS7-PV-20 27 CS7-PVB-20 42
CA7-30...97--00 CA7-PV-20 27 CA7-PVB-20 42
1EM 1LB CA7-30...97--00 CA7-PV-L11 37 NOT AVAILABLE ~
1 3
54
53
62
61
72
71
82
81
CA7-30...97--00 NOT AVAILABLE ~ CA7-PVB-13 79
2 2
54
53
62
61
72
71
84
83
CA7 all CS7-PV-22 53 CS7-PVB-22 79
CA7-30...97--00 CA7-PV-22 53 CA7-PVB-22 79
22
21
32
31
44 54
5343 CA7-9...23--10CA7-PV-S22 53 CA7-PVB-S22 79
CA7-9...23--01
3 154
53
62
61
74
73
84
83
CA7 all CS7-PV-31 53 CS7-PVB-31 79
22
21
34
33
44
43
54
53CA7-9...23--10
CA7-PV-S31 53 CA7-PVB-S31 79CA7-9...23--01
1 3
54
53
62
61
72
71
82
81
CA7 all CS7-PV-13 53 CS7-PVB-13 79
4 054
53
64
63
74
73
84
83
CA7 all CS7-PV-40 53 CS7-PVB-40 79
0 4
52
51
62
61
72
71
82
81
CA7 all CS7-PV-04 53 CS7-PVB-04 79
1+1EM 1+1LB
54
53
62
61
76
75
88
87
CA7 all CS7-PV-L22 74 NOT AVAILABLE ~
Top mount auxiliary contactblocks snap-on to the top (front)
of any CA7 contactor
4-pole auxiliary
2-pole auxiliarycontact block (typical)
Top (Front) Mount Auxiliary Contact Blocks
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
12/19A48
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Side Mount Auxiliary Contact Blocks (1 & 2 Pole)
Max. number of auxiliary contacts that may be mounted:
AC Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O.
contacts on the side, 4-N.C. front or side: 6 total.
DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max.
2-N.O. contacts on side, 4-N.C. front or side: (4) total.
Left mounting only is recommended when using with CA7-9CA7-23 contactors.
These contactors have built-in auxiliaries, which will result in duplicate terminal
markings if mounted on the right.
Detailed ratings can be found on page A74.
Accessories Field Installable
CA7 Contactors
Contact Block Description NO NCContact
Arrangement For use with... Catalog Number Price
0 1 CA7 all CA7-PA-01 17
1 0 CA7 all CA7-PA-10 17
0 2 CA7 all CA7-PA-02 27
1 1 CA7 all CA7-PA-11 27
2 0 CA7 all CA7-PA-20 27
1EM 1LB CA7 all CA7-PA-L11 37
1-pole (typical)
2-pole (typical)
Auxiliary Contact Blocks for Side
Mounting -
1 and 2-pole
Two way numbering for right or left
mounting on the contactor
Snap-on design - mounts without
tools
Electronic compatible contacts down
to 24V, 20mA
Late break / early make (L) available
Mutual positive guidance to the main
contactor poles (excluding L-types)
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
13/19
A49visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Accessories Field Installab
CA7 Contacto
Control Modules
Module DescriptionFor usewith. . . Connection Diagrams Function Catalog Number Pric
Pneumatic Timing Module The contacts in the Pneumatic TimingElement switch after the delay time. Thecontacts on the main contactor continueto operate without delay.
Continuous adjustment range
CA7 allON-Delay
0.330s1.8180s
CZE7-30
CZE7-180
160
CA7 all OFF-Delay0.330s1.8180s
CZA7-30CZA7-180
160
Electronic Timing Module ON-DelayThe contactor is energized at the end ofthe delay time.
CA7 all
110240V 50/60Hz110250V DC
CRZE7-3-110/240CRZE7-30-110/240CRZE7-180-110/240
980.13s130s10180s
2448V DCCRZE7-3-24/48VDCCRZE7-30-24/48VDCCRZE7-180-24/48VDC
1040.13s130s10180s
Electronic Timing Module OFF-DelayAfter interruption of the control signal, thecontactor is de-energized at the end of thedelay time.
CA7 all
110240V 50/60Hz
CRZA7-3-110/240CRZA7-30-110/240CRZA7-180-110/240
1120.33s130s10180s
CA7-9CA7-37
24V AC 50/60Hz
CRZA7-3-24VACCRZA7-30-24VACCRZA7-180-24VAC
1120.33s130s10180s
Electronic Timing Module Wye-Delta Transition TimerContactor K3 (Y) is de-energized andcontactor K2 (D) is energized after the endof the set transition time. Switching delayat 50ms.
Continuous adjustment range High repeat accuracy
CA7 all K1 (H) K2(D)
K3 (Y)
K1
K2
K3
110240V 50/60HzCRZY7-30-110/240 112
130s
CM7 CM7-02
Mechanical/Electrical Interlocks
Common to all CA7 contactors;interlocks different contactor sizes
Mechanical and electrical interlockingpossible in one module by means ofintegrated auxiliary contacts
Dovetail (CA7-S9) connector included(9mm)
CA7 all
MechanicalWithout auxiliaries CM7
34
22
21
22
21 Mechanical/ElectricalTwo NC aux contacts
CM7-0240
Not for use with CA7-40 or CA7-90 (4-pole) Contactors.
Not available for use on CA7-9E43E coil voltage 48V220V.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
14/19
A50
Co
ntactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Control Modules(continued)
Module DescriptionFor usewith
ConnectionDiagrams Catalog Number Price
Mechanical Latch Following contactor latching, the contactor coilis immediately de-energized by the NC auxiliarycontact (65-66).
Electrical or manual release 1 NO + 1 NC auxiliary switch Suitable for all CA7 contactors
CA7-997
CV7-11-Replace withcoil code below(See ApplicationNote below)
94
Accessories Field Installable
CA7 Contactors
CV7 Mechanical Latch Coil Codes APPLICATION NOTE:The CV7 Mechanical Latch for CA7 may be used for both AC and
DC applications; however when using DC control circuit the user
must apply the following rules for coil selection of the contactorand latch combination:
When DC control circuits are required use CA7-943
contactors with AC coil and latch with AC coil. From column
VDC in the table on the left, identify the required application
DC control voltage and then select its specific Coil Code. Enter
this Coil Code to complete the catalog numbers for both the
contactor and latch (i.e.: 125V DC control circuit should use a
240Z coil code in both the CA7-943 and CV7). This works
because both coils are only momentary energized and coil
clearing contacts breaks the circuit after closing or opening.
The above statement does NOT apply to applications CA7-
60D97D two-winding DC coil contactors. When DC control
circuits are required use CA7-60D97D contactors withstandard two winding DC coil and the CV7 latch with AC coil
selected from the table, top left. (i.e.: 125V DC control circuit
should use 125DD coil code in the contactor and 240Z AC coil
code in the CV7 latch).
The CA7-9E43E contactor uses an electronic DC coil and the
CV7 latch coil code should be chosen from the table on the left.
(i.e.: 24V DC control circuit select CA7-9E43E with code 24E
and CV7 latch uses a 48Z AC coil code).
Coil
Code
Application Range Latch & Contactor Coil
Rating50 Hz 60 Hz VDC
24Z 24 VAC 24 VAC 12 VDC 24V 50/60 Hz
48Z 48 VAC 48 VAC 24 VDC 48V 50/60 Hz
110 100 VAC 110 VAC 48 or 60VDC 110V50/110V60
120 110 VAC 120 VAC ~ 110V50/120V60
220W ~ 208240 VAC ~ 208240V60
230Z 230 VAC 230 VAC 110 VDC 230V 50/60 Hz
240Z 240 VAC 240 VAC 125 VDC 240V 50/60 Hz
277 240 VAC 277 VAC ~ 240V50/277V60
380 380400 VAC 440 VAC ~ 380400V50/440V60
400Z 400 VAC 400 VAC 220 VDC 400V 50/60 Hz
415 400415 VAC ~ ~ 400415 V50 Hz
480 440 VAC 480 VAC ~ 440V50/480V60
600 550 VAC 600 VAC ~ 550V50/600V60
Other voltages available. Contact your Sprecher + Schuh representative.
CV7 must be wired for momentary operation only.
Use 600V AC when 575 V is required.
Command duration 0.0310 seconds.
Coil operating limits on CV7-11 match those of the contactor it is being used with.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
15/19A51visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Control Modules(continued)
Module DescriptionFor usewith
ConnectionDiagrams Function Catalog Number Price
Electronic Interface
Interface between the DC controlsignal from a PLC and the AC operatingmechanism of the contactor.
Requires no additional surge suppres-sion for the coils
Switching capacity 200VA
Suitable for all CA7 contactors
CA7 all(with ACcontrol)
Input Output
72
24V DC 110 CRI7E-24
12V DC 240V AC CRI7E-12
48V DC CRI7E-48Indicates special order
Surge Suppressors -Limits coil switching transients.
Plug-in, coil mounted Suitable for all CA7 contactors
CA7 all
RC Module -AC Control (50/60Hz)
2448V CRC7-4834
110280V CRC7-280
380480V CRC7-480
Diode Module -DC Control
3412-250VDC CRD7-250
Varistor Module -AC/DC Control
34
1255VAC/1277VDC
CRV7-55
56136VAC/78180VDC
CRV7-136
137277VAC/181350VDC
CRV7-277
278575VAC CRV7-575
Accessories Field Installabl
CA7 Contactor
Control voltage 1830V DC (1015mA)
Minimum actuation current is 5 volts, 2ma. The leakage current is
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
16/19A52
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Module Description
Full-Wave Bridge Rectifier
Catalog
NumberPrice
Module Input Module Output
Control circuit voltage range
For use with
CA7 contactors with DC coilCS7 control relays with DC coil
SEMI-F47-Module 24-250 VAC 24-250 VDC CA7-SF47 109
Semi-F47-Module
with 1...30s
on-delay timer
110-250 VAC 110-250 VDC CA7-SF47A30 175
100
90
80
70
60
5040
30
20
10
0
0.05 0.1 0.2 0.5 1.0
Duration of Voltage Sag in Seconds
PercentageofEqui
pmentNominalVoltage
Semi-F47 Modules
For CA7 Contactors
AC Voltage Sag Immunity Modules
Sprecher + Schuhs CA7-SF47 module meets the Semi-F47 AC voltage sag immunity requirements to 50% voltage sag for 200 ms. Voltage sags can affect
the readiness and operation of contactors and starters, resulting in shut downs, lost production, and diminished revenue. It is essential for process equip-
ment to be compatible with its electrical environment. The CA7-SF47 voltage sag immunity module is an essential component to achieve equipment reli-
ability during voltage sag events.
Product Features
Meets Semi-F47 standard requirements
For use with CA7 contactors and CS7 control relays
with DC coils. A full-wave bridge rectifier internal to
the CA7-SF47 module provides AC to DC coil voltage
rectification.
Suitable for contactor range (with screw terminals)
- CA7-9 ... 97, 3-Pole contactors
- CA7-9 ... 90, 4-Pole contactors
Suitable for control relays (with screw terminals) - CS7
Optional 1 to 30 seconds On-Delay timer function.
Benefits
Direct mounting to the coil terminals of the CA7
contactors and CS7 control relays. Only 24 mm is added
to the component height.
Direct electrical connection to the contactor or control
relay. Customer coil power connections are made at the
terminals of the CA7-SF47 module
The CA7-SF47A30 module includes a 1 to 30 seconds
adjustable On-Delay timer in addition to the voltage sag
immunity functionality. Two independent functions in a
single module.
VOLTAGE SAG DURATION VOLTAGE SAG
Seconds Milliseconds Cycles at 60 hz Cycles at 50 hz Percent (%) of Equipment Nominal Voltage
< 0.05 s < 50 ms < 3 cycles < 2.5 cycles Not specified
0.05 to 0.2 s 50 to 200 ms 3 to 12 cycles 2.5 to 10 cycles 50%
0.2 to 0.5 s 200 to 500 ms 12 to 30 cycles 10 to 25 cycles 70%
0.5 to 1.0 s 500 to 1000 ms 30 to 60 cycles 25 to 50 cycles 80%
> 1.0 s > 1000 ms > 60 cycles > 50 cycles Not specified
Input AC control circuit voltage must be matched when selecting the contactor/relay DC coil voltage.
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
17/19A53visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012
Discount Schedule A-1
Terminal Lug Kits
Paralleling Links
cULus Approved (File E33916).
Lighting applications are not considered purely resistive loads. Therefore, the IEC
and UL/CSA resistive ratings listed here do not apply to lighting loads. Lighting
contactor ratings are provided in the Technical Information section.
Priced per piece. Total cost is package quantity x price. Minimum order, 3 pieces
Engineering practice permits 2.5 x Ieto be applied to a contactor when 3 poles ar
connected in parallel for single phase discharge lamp (ballast lighting) applicatio
Component Description
For use
with . . .
Maximum ResistiveCurrent Ratings (A)
Pkg.
Qty.
Catalog
Number
Price
EachIEC
(40C)IEC
(60C)UL/CSA(40C)
3 Pole Lug Kit Allows larger wires to beused with the contactor. Idealfor wye-delta, reversing andmultispeed contactors andstarters. Can increase IECAC-1 current rating, as wellas the UL/CSA continuouscurrent (resistive) rating ofthe contactor. Three pole kitused for smaller contactors.
CA7-9. . .23
-line side
-load side
45 45 40 1CA7-P-KN23
CA7-P-KL2341
CA7-30. . .37 60 55 55 1 CA7-P-K37 56
1 Pole Lug Kit Allows larger wires to be
used with the contactor.Ideal for wye-delta, reversingand multispeed contactorsand starters. Can increaseAC-1 current rating of thecontactor. One pole kit usedfor larger contactors.
CA7-43 90 75 75 3 CA7-P-K43
28
Each
CA7-60 . . .97 130 130 130 3 CA7-P-K85
33
Each
Component Description
For use
with . . .
Maximum ResistiveCurrent Ratings (A)
Pkg.
Qty.CatalogNumber
Price
EachIEC
(40C)IEC
(60C)UL/CSA(40C)
3 Pole Paralleling Link Allows smaller CA7contactors to be used onsingle-phase resistiveapplications. By parallelingthe three power poles, thecontacts see only a portion ofthe actual load.
CA7-9. . .23 100 100 100 2 CA7-P-B23
10
Each
CA7-30. . .37 150 135 150 2 CA7-P-B37
15
Each
Quick Connectors
Component Description For use with . . .
Pkg.
Qty. Catalog Number
Price
Each
Stab Connectors -Dual stab (0.250 inch)
CA7-997 coil term.CA7-923 power term.CA7 accessories
20
100
100
CA7-SC2CA7-SC10CA4-SC11
1.75
Accessories Field Installab
CA7 Contactor Terminal Lug Ki
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
18/19A54
Contactors
A
visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012
CA7
Discount Schedule A-1
Reversing Components
Accessories Field Installable
CA7 Contactors
cULus Approved (File E33916).
Component Description For Use WithPkg.Qty. Catalog Number
PriceEach
Dovetail Connectors Connects multiple contactor and starterassemblies together.
CA7 all 10 CA7-S9 1.75
Reversing Power Wiring Kit - Provides a solid wireless connectionfor reversing applications. May be usedwith both solid state and thermal O/Lrelays.
CA7-912CA7-1623
1 CAUT7-PW2317
CA7-3037CA7-43CA7-6097
1
1
1
CAUT7-PW37CAUT7-PW43CAUT7-PW85
20
37
94
Reversing Power Wiring KitsOnly the kits are catalog items. Single components
are available by special order in bulk packages of
20 pieces.
Assembly Components
Component Description For Use WithPkg.Qty. Catalog Number
PriceEach
Protective Covers -Protects against unintended manualoperation.
CA7 all 1
CA7-SCC 3.35
Protective Covers -For front mounted auxiliary contacts,pneumatic timers and latches.
CS7-PV, CA7-PV,CZE7, CZA7, CV7
1 CA7-SCF 1.75
DIN-rail- 2 meter lengths ( 6' 6");
price per rail
Top Hat, low profile
Top Hat, high profile
CA7 all 20
10
3F3AF
29
44
Marking Systems
Component DescriptionPkg.Qty. Catalog Number
PriceEach
Label Sheet 1 sheet with 105 self-adhesive paperlabels each, 6 x 17mm
1 CA7-FMS 1.75
Marking Tag Sheet -1 sheet with 160 perforated paperlabels each, 6 x 17mm. To be used withtransparent cover.
1 CA7-FMP 1.75
Transparent Cover -To be used with Marking Tag Sheets.
100
CA7-FMC.17
Tag Carrier -For marking with Clip-on Tags. SeeTerminals Section N for complete listingof Clip-on Tags.
100
CA7-FMA2.17
CA7-60..97CA7-60..97
-
8/9/2019 Sprecher Schuh CA7_Contactors.pdf
19/19
CA7-PWLM37 CA7-PWLM43
CA7-PWLM85
CA7-PWD43 CA7-PWD43
CA7-PWD85
2M S 2M S
2M S
C A7 -6 0. .9 7 C A7 -6 0. .9 7
CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97
cULus Approved (File E33916).
Individual parts of kits are available for unique applications by special order. Contact your Sprecher + Schuh Representative.
Accessories Field Installab
CA7 Contacto
Wye-Delta Starter Kits Wye-Delta power wiring kits were designed to aid in the field assembly of open-transition wye-
delta starters that use CA7 contactors. These kits include line, load and start-point (shorting)
connections. Assembling a wye-delta starter requires the use of the following components:
Contactors and overload relay
Mechanical / Electrical Interlock(Cat.No: CM7-02)
Electronic Wye-delta Timer(Cat. No: CRZY7-30-110/240)
Dovetail Connector to couple 1M and 2M contactor(Cat. No: CA7-S9); optional
Three Contactor Assembly Components
3-Phase Rating For 3 contactor
assembly
Catalog Number Price
kW (50Hz) HP (60Hz) Use with catalog number . . .
230V
380V
415V 500V 690V 200V 230V 460V 575V
Delta Wye
1M 2M 1S
5.5 8 8 8 5 5 10 10 CA7-9 CA7-9 CA7-9
CAYT7-PW23 227.5 11 11 11 5 7.5 15 15 CA7-12 CA7-12 CA7-9
10 14 15 14 7.5 10 20 20 CA7-16 CA7-16 CA7-12
14 21 21 19 7.5 10 25 25 CA7-23 CA7-23 CA7-12
18 28 28 28 10 15 30 30 CA7-30 CA7-30 CA7-16CAYT7-PW37 27
19 35 35 32 15 20 40 40 CA7-37 CA7-37 CA7-23
23 40 40 41 20 25 50 50 CA7-43 CA7-43 CA7-30 CAYT7-PW43 44
33 58 60 56 30 40 75 75 CA7-60 CA7-60 CA7-37CAYT7-PW72 79
39 69 67 70 40 50 100 100 CA7-72 CA7-72 CA7-43
47 82 82 81 50 60 125 125 CA7-85 CA7-85 CA7-60CAYT7-PW85 106
50 90 90 90 50 60 125 125 CA7-97 CA7-97 CA7-60
Two Contactor Assembly Components
When Connecting... Load Side PowerConnection
Catalog Number Price
Shorting Bar
CatalogNumber Price
Delta Wye
2M 1S
CA7-30 CA7-30CA7-PWLM37 11 CA7-PWD43 14
CA7-37 CA7-37
CA7-43 CA7-43 CA7-PWLM43 18 CA7-PWD43 14
CA7-60 CA7-60
CA7-PWLM85 46 CA7-PWD85 23CA7-72 CA7-72
CA7-85 CA7-85
CA7-97 CA7-97
Power Jumper Connection Shorting Bar
Reversing Power Connection
Two Contactor Wiring
Connections are for
Hydraulic Elevator Wye-
Delta Contactors CA7Y2