bosch_solar_module_µm_si_plus_eu1310_englisch
TRANSCRIPT
7/29/2019 Bosch_Solar_Module_µm_Si_plus_EU1310_englisch
http://slidepdf.com/reader/full/boschsolarmodulemsipluseu1310englisch 1/2
High-yield – easy-to-assemble – reliable.
Solar modules rom Bosch Solar Energy.
Reliable system – high yields.Bosch Solar Module μm-Si plusEU1310
Our thin-flm modules oer impressive eatures including:
Excellent annual yields or you and your customers,
using non-toxic materials
Higher specifc yields due to positive power sorting
Assembly systems that complement one another perectly and
are supplied rom a single source thanks to collaborations with
major assembly system manuacturers, including Bosch Rexroth
Straightorward, solid installation with low assembly outlay
through adaptability o recognized standard components
Good usage options on e.g. east-acing, west-acing and slightly
sloping roos
Solar panels do not require grounding in use Bosch Solar Rack
products1
Our certifcates – quality stamped in writing
Bosch Solar Energy modules go through strict quality tests during the dierent
stages o production according to international standards.
ASSOCIATION
Quality
Product certifcation to IEC 61646
and IEC 61730
Product eatures
Perormance sorting –0/+4.99 Wp
Temperature coefcient Pmpp
–0.33 %/K
Components
Thermally strengthened ront and rear glass,
MC4, Multi-junction-cell
Value chain
Cell – Module
Warranty
5 years product warranty
25 years perormance guarantee
(90 % up to 12 years, 80 % up to 25 years)
Power classes
100 – 120 Wp
7/29/2019 Bosch_Solar_Module_µm_Si_plus_EU1310_englisch
http://slidepdf.com/reader/full/boschsolarmodulemsipluseu1310englisch 2/2
Bosch Solar Module μm-Si plus | EU1310
Permissible operating and
assembly conditions:
Temperature range –40 °C
to +85 °C, humidity max.
85 % (rh)
Upright assembly, laser lines
running vertically
Panels must be unshadedduring installation and
operation
Mechanical load-bearing
capacity tested up to 2400 Pa
Transormerless DC-AC
converters are not permitted
Maximum 1000 V system
voltage
Reverse-current load capacity
(Ir) 6 A
Weak light perormance:
Intensity
[W/m2]
Vmpp
[%]
Impp
[%]
800 –1.5 –19
600 –3.0 –39
400 –5.0 –58
200 –9.0 –78
The electrical data applies or
25 °C and AM 1.5.
Thin-flm solar module
Perormance classes 100 Wp, 105 Wp, 110 Wp, 115 Wp, 120 Wp
Perormance sorting –0/+4.99 Wp
Structure Frameless glass-glass laminate
Thermally strengthened ront glass
PVB (white) or EVA oil
Thermally strengthened rear glass
Junction box without bypass diode
Plug connector system MC4
IP-Code Junction Box (IP 65)
Cells Amorphous and microcrystalline silicon Multi-junction cell
Designation Pmpp
[Wp]
Vmpp
[V]
Impp
[A]
Voc
[V]
Isc
[A]
Voc initial
[V]
Isc initial
[A]
μm-Si plus 120 120 64 1.90 86 2.30 89 2.32μm-Si plus 115 115 64 1.82 86 2.23 89 2.27
μm-Si plus 110 110 64 1.75 86 2.17 89 2.23
μm-Si plus 105 105 64 1.66 86 2.07 89 2.16
μm-Si plus 100 100 64 1.60 86 2.01 89 2.05
Reduction in module eiciency with decrease in irradiation level rom 1000 W/m² to 200 W/m² (at 25 °C):
–0.60 % (absolute); Measurement tolerance Pmpp ±5 %
Electrical characteristics or STC2:
Length
[x]
Width
[y]
Height
[z]
Weight Junction
box
Plug
connector
Cable
[l]
1300 1100 7.1 25 MultiContact MC4 Plus 500
Minus 1 000
x, y, l in mm, –1 / +4 mm; z in mm, ±0.5 mm; weight in kg ±0.7
Designation Pmpp
[W]
Vmpp
[V]
Voc
[V]
Isc
[A]
μm-Si plus 120 91 59 79 1.86
μm-Si plus 115 87 59 79 1.81
μm-Si plus 110 84 59 79 1.76μm-Si plus 105 80 59 79 1.68
μm-Si plus 100 77 59 79 1.63
NOCT: Normal Operation Cell Temperature 48 °C: Irradiation level 800 W/m², AM 1.5, temperature 20 °C,
wind speed 1 m/s, electrical open circuit operation
Electrical characteristics or NOCT2:
The relevant and valid assembly instructions must be ollowed as mandatory. Bosch Solar Energy AG accepts no
liability or damage to equipment that has been operated using modules rom Bosch Solar Energy AG on the basis o
inormation not supported by technical datasheets. Subject to technical modifcations in the course o product
development and mistakes/errors.
1 Other mounting systems may have restrictions. Follow the instructions in the installation guide.2 Electrical parameters are typical mean values rom historical production data. Bosch Solar Energy AG does not
assume any guarantee or the accuracy o this data or uture production batches. All data and fgures are subject to
a tolerance o 10 %, unless specifed otherwise. The measurement tolerance fgure or NOCT and low light
perormance reers to the relative output (Pmpp).3 Drawings and diagrams are not to scale. Detailed dimensions and tolerances are available on request.
Temperatur-
coefzient
TK
[%/K]
Pmpp –0.33
Uoc –0.37
Isc 0.08
Measurement tolerance ±0.04 %/K
Bosch Limited -
Solar Energy Division
Hosur Road, Adugodi
Bangalore - 560 030
India
Phone: +91 80 2299 2366
Mobile: +91 9741496854
Version: 01/2012
Dimensions3: